Line 34: Line 34:
!Example
!Example
|-
|-
|Controller
|General
|Show configs
|Show all controller configs on the system
|<code>hpssacli ctrl all show config</code>
|<code>hpssacli ctrl all show config</code>
|
|
|-
|-
|
|
|Controller status
|Show all controller statuses
|<code>hpssacli ctrl all show status</code>
|<code>hpssacli ctrl all show status</code>
|
|
|-
|-
|
|
|Show detailed controller information for all controllers
|Show detailed information on all controllers on the system
|<code>hpssacli ctrl all show detail</code>
|<code>hpssacli ctrl all show detail</code>
|
|
|-
|-
|
|
|Rescan for new controllers
|<code>hpssacli rescan</code>
|
|-
|Controller specific
|Show detailed controller information for controller in slot 0
|Show detailed controller information for controller in slot 0
|<code>hpssacli ctrl slot=0 show detail</code>
|<code>hpssacli ctrl slot=0 show detail</code>
Line 55: Line 60:
|-
|-
|
|
|Enable Drive Write Cache
|Enable Drive Write Cache on controller 0
|<code>hpssacli ctrl slot=0 modify dwc=enable</code>
|<code>hpssacli ctrl slot=0 modify dwc=enable</code>
|
|
|-
|-
|
|
|Disable Drive Write Cache
|Disable Drive Write Cache on controller 0
|<code>hpssacli ctrl slot=0 modify dwc=disable</code>
|<code>hpssacli ctrl slot=0 modify dwc=disable</code>
|
|
|-
|-
|
|
|Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)
|Modify smart array cache read and write ratio on controller 0
cacheratio=readratio/writeratio
|<code>hpssacli ctrl slot=0 modify cacheratio=100/0</code>
|<code>hpssacli ctrl slot=0 modify cacheratio=100/0</code>
|
|
Line 72: Line 78:
|Enable smart array write cache when no battery is present (No-Battery Write Cache option)
|Enable smart array write cache when no battery is present (No-Battery Write Cache option)
|<code>hpssacli ctrl slot=0 modify nbwc=enable</code>
|<code>hpssacli ctrl slot=0 modify nbwc=enable</code>
|
|-
|
|Rescan for New Devices
|<code>hpssacli rescan</code>
|
|
|-
|-
Line 159: Line 160:
|
|
|-
|-
|Array
|Add Spare Disks for all arrays
|<code>hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7</code>
|
|
|Add Spare Disks
|-
|<code>hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7</code>
|
|Remove a disk from an array
|<code>hpssacli ctrl slot=0 array A remove drives=2I:1:6</code>
|
|
|-
|-
|
|
|Enable SSD Smart Path
|Enable SSD Smart Path
|<code>hpssacli ctrl slot=0 array a modify ssdsmartpath=enable</code>
|<code>hpssacli ctrl slot=0 array A modify ssdsmartpath=enable</code>
|
|
|-
|-
|
|
|Disable SSD Smart Path
|Disable SSD Smart Path
|<code>hpssacli ctrl slot=0 array a modify ssdsmartpath=disable</code>
|<code>hpssacli ctrl slot=0 array A modify ssdsmartpath=disable</code>
|
|
|}
|}

Revision as of 17:07, 29 October 2020

HP Smart Storage Administrator, also abbreviated as HP SSA, is the set of utilities used to manage HP Raid controllers.

Linux

Get the Linux RPM package from https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d6ebba0f5cd642edace4648b9a. Alternatively, search online for 'hpacucli'

The package will be placed in /opt/compaq/hpacucli/bld/.

root@x:/root# /opt/compaq/hpacucli/bld/hpacucli ctrl all show  config

Smart Array P410i in Slot 0 (Embedded)    (sn: 50014380236B2020)

   array A (SAS, Unused Space: 0  MB)


      logicaldrive 1 (279.4 GB, RAID 1, OK)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)

   unassigned

      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 1 TB, OK)

   SEP (Vendor ID PMCSIERA, Model  SRC 8x6G) 250 (WWID: 50014380236B202F)

Quick Usage

Task Command Example
General Show all controller configs on the system hpssacli ctrl all show config
Show all controller statuses hpssacli ctrl all show status
Show detailed information on all controllers on the system hpssacli ctrl all show detail
Rescan for new controllers hpssacli rescan
Controller specific Show detailed controller information for controller in slot 0 hpssacli ctrl slot=0 show detail
Enable Drive Write Cache on controller 0 hpssacli ctrl slot=0 modify dwc=enable
Disable Drive Write Cache on controller 0 hpssacli ctrl slot=0 modify dwc=disable
Modify smart array cache read and write ratio on controller 0

cacheratio=readratio/writeratio

hpssacli ctrl slot=0 modify cacheratio=100/0
Enable smart array write cache when no battery is present (No-Battery Write Cache option) hpssacli ctrl slot=0 modify nbwc=enable
Physical Disks Physical disk status hpssacli ctrl slot=0 pd all show status
Show detailed physical disk information hpssacli ctrl slot=0 pd all show detail
Erase Physical Drive hpssacli ctrl slot=0 pd 2I:1:6 modify erase
Re-enable Physical Drive hpssacli ctrl slot=0 pd 2I:1:6 modify reenable
hpssacli ctrl slot=0 pd 2I:1:6 modify
Logical Disks Logical disk status hpssacli ctrl slot=0 ld all show status
View Detailed Logical Drive Status hpssacli ctrl slot=0 ld 2 show
Create New RAID 0 Logical Drive hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
Create New RAID 1 Logical Drive hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
Create New RAID 5 Logical Drive hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
Delete Logical Drive hpssacli ctrl slot=0 ld 2 delete
Add New Physical Drive to Logical Volume hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7
Turn on Blink Physical Disk LED hpssacli ctrl slot=0 ld 2 modify led=on
Turn off Blink Physical Disk LED hpssacli ctrl slot=0 ld 2 modify led=off
Disable smart array cache for certain Logical Volume hpssacli ctrl slot=0 ld 1 modify arrayaccelerator=disable
Enable smart array cache for certain Logical Volume hpssacli ctrl slot=0 ld 1 modify arrayaccelerator=enable
Array Add Spare Disks for all arrays hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7
Remove a disk from an array hpssacli ctrl slot=0 array A remove drives=2I:1:6
Enable SSD Smart Path hpssacli ctrl slot=0 array A modify ssdsmartpath=enable
Disable SSD Smart Path hpssacli ctrl slot=0 array A modify ssdsmartpath=disable

Troubleshooting

Replaced a drive, but it still shows as failed

Prior to the disk replacement, dmesg showed this:

hpsa 0000:03:00.0: scsi 1:0:7:0: removed Direct-Access     HP       EG1200FDNJT      PHYS DRV SSDSmartPathCap- En- Exp=0  

Replacing the disk didn't create a new message in dmesg as others have noted. The configs still show the physical drive as failed.

# hpssacli ctrl slot=0 show config                          
                                                                           
Smart Array P410i in Slot 0 (Embedded)    (sn: 5001438020D43A50)           
                                                                           
   array A (SAS, Unused Space: 0  MB)                                      
                                                                           
                                                                           
      logicaldrive 1 (136.7 GB, RAID 0, OK)                                
                                                                           
      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 72 GB, OK)           
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 72 GB, OK)           
                                                                           
   array B (SAS, Unused Space: 0  MB)                                      
                                                                           
                                                                           
      logicaldrive 2 (5.5 TB, RAID 5, Interim Recovery Mode)               
                                                                           
      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 1200.2 GB, OK)       
      physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 1200.2 GB, OK)       
      physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 1200.2 GB, OK)       
      physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 1200.2 GB, OK)       
      physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 1200.2 GB, Failed)   
      physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 1200.2 GB, OK)       
                                                                           
   SEP (Vendor ID PMCSIERA, Model  SRC 8x6G) 250 (WWID: 5001438020D43A5F)  

# hpssacli ctrl slot=0 ld all show

Smart Array P410i in Slot 0 (Embedded)

   Array A

      logicaldrive 1 (136.7 GB, RAID 0, OK)

   Array B

      logicaldrive 2 (5.5 TB, RAID 5, Interim Recovery Mode)

# hpssacli ctrl slot=0 ld 2 modify reenable                                         
                                                                                                   
Warning: Any previously existing data on the logical drive may not be valid or                     
         recoverable. Continue? (y/n) y                                                            
                                                                                                   
                                                                                                   
Error: This operation is not supported with the current configuration. Use the                     
       "show" command on devices to show additional details about the                              
       configuration.                                                                              
Reason: Array status not ok

# hpssacli ctrl slot=0 array B remove drives=1:7

Error: This operation is not supported with the current configuration. Use the
       "show" command on devices to show additional details about the
       configuration.
Reason: Array is transforming

Next thing to try is to reboot the server and check the RAID via the BIOS.