HP Smart Storage Administrator: Difference between revisions

From Leo's Notes
This page was last edited on 9 October 2020, at 15:50.
m Added example commands
Line 27: Line 27:
}}
}}


=== Quick Usage ===
===Quick Usage===
{| class="wikitable"
{| class="wikitable"
!Task
!Task
Line 86: Line 86:
|-
|-
|Add New Physical Drive to Logical Volume
|Add New Physical Drive to Logical Volume
|<code>pssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7</code>
|<code>hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7</code>
|
|
|-
|-
Line 140: Line 140:
==See Also==
==See Also==


*https://djfueese.blogspot.ca/2016/08/hp-smart-storage-administrator-hp-ssa.html
*https://djfueese.blogspot.ca/2016/08/hp-smart-storage-administrator-hp-ssa.html (offline)




{{Navbox Linux}}
{{Navbox Linux}}
[[Category:Linux]]
[[Category:Linux]]

Revision as of 15:50, 9 October 2020

HP Smart Storage Administrator, also abbreviated as HP SSA, is the set of utilities used to manage HP Raid controllers.

Linux

Get the Linux RPM package from https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d6ebba0f5cd642edace4648b9a. Alternatively, search online for 'hpacucli'

The package will be placed in /opt/compaq/hpacucli/bld/.

root@x:/root# /opt/compaq/hpacucli/bld/hpacucli ctrl all show  config

Smart Array P410i in Slot 0 (Embedded)    (sn: 50014380236B2020)

   array A (SAS, Unused Space: 0  MB)


      logicaldrive 1 (279.4 GB, RAID 1, OK)

      physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK)
      physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK)

   unassigned

      physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 1 TB, OK)

   SEP (Vendor ID PMCSIERA, Model  SRC 8x6G) 250 (WWID: 50014380236B202F)

Quick Usage

Task Command Example
Show controller config hpssacli ctrl all show config
Controller status hpssacli ctrl all show status
Show detailed controller information for all controllers hpssacli ctrl all show detail
Show detailed controller information for controller in slot 0 hpssacli ctrl slot=0b show detail
Rescan for New Devices hpssacli rescan
Physical disk status hpssacli ctrl slot=0b pd all show status
Show detailed physical disk information hpssacli ctrl slot=0b pd all show detail
Logical disk status hpssacli ctrl slot=0b ld all show status
View Detailed Logical Drive Status hpssacli ctrl slot=0 ld 2 show
Create New RAID 0 Logical Drive hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
Create New RAID 1 Logical Drive hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
Create New RAID 5 Logical Drive hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
Delete Logical Drive hpssacli ctrl slot=0 ld 2 delete
Add New Physical Drive to Logical Volume hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7
Add Spare Disks hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7
Enable Drive Write Cache hpssacli ctrl slot=0 modify dwc=enable
Disable Drive Write Cache hpssacli ctrl slot=0 modify dwc=disable
Erase Physical Drive hpssacli ctrl slot=0 pd 2I:1:6 modify erase
Turn on Blink Physical Disk LED hpssacli ctrl slot=0 ld 2 modify led=on
Turn off Blink Physical Disk LED hpssacli ctrl slot=0 ld 2 modify led=off
Modify smart array cache read and write ratio (cacheratio=readratio/writeratio) hpssacli ctrl slot=0 modify cacheratio=100/0
Enable smart array write cache when no battery is present (No-Battery Write Cache option) hpssacli ctrl slot=0 modify nbwc=enable
Disable smart array cache for certain Logical Volume hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable
Enable smart array cache for certain Logical Volume hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable
Enable SSD Smart Path hpssacli ctrl slot=0 array a modify ssdsmartpath=enable
Disable SSD Smart Path hpssacli ctrl slot=0 array a modify ssdsmartpath=disable

See Also