Smart Meters: Difference between revisions

From Leo's Notes
This page was last edited on 16 March 2025, at 20:43.
Created page with " == Reading Smart Meters with rtlamr / RTL-SDR == Smart reader data can be read using a DVB-TV (RTL2832U) tuner with RTL-SDR using [https://github.com/bemasher/rtlamr rtlamr]...."
 
mNo edit summary
 
(2 intermediate revisions by the same user not shown)
Line 13: Line 13:
}}
}}


The {{code|rtl_tcp}} binary should now be in the build/src directory. Next, build the {{rtlamr}} binary by installing Go.
The {{code|rtl_tcp}} binary should now be in the build/src directory. Next, build the {{code|rtlamr}} binary by installing Go.


{{highlight|lang=terminal|code=
{{highlight|lang=terminal|code=
Line 21: Line 21:
}}
}}


Run both the {{code|rtl_tcp}} and {{code|rtlamr}} binary. The output from {{rtlamr}} should look something similar to:
Run both the {{code|rtl_tcp}} and {{code|rtlamr}} binary. The output from {{code|rtlamr}} should look something similar to:
{{highlight|lang=text|code=
{{highlight|lang=text|code=
<nowiki>
<nowiki>
Line 32: Line 32:


The next step is to find out which meter is yours and then log the value somewhere.
The next step is to find out which meter is yours and then log the value somewhere.
{{Navbox Tinkering}}[[Category:Tinkering]]

Latest revision as of 20:43, 16 March 2025

Reading Smart Meters with rtlamr / RTL-SDR

Smart reader data can be read using a DVB-TV (RTL2832U) tuner with RTL-SDR using rtlamr.

To get this working, first compile RTL-SDR:

# yum -y install cmake libusb-devel
# git clone git://git.osmocom.org/rtl-sdr.git
# cd rtl-sdr
# mkdir -p build
# cd build
# cmake .. && make

The rtl_tcp binary should now be in the build/src directory. Next, build the rtlamr binary by installing Go.

## Download Go and extract it. The go binary should just work.
## Export your GOPATH which will be where the source/binary will be saved to
# go get github.com/bemasher/rtlamr

Run both the rtl_tcp and rtlamr binary. The output from rtlamr should look something similar to:

{Time:2019-01-03T19:17:29.986 SCM:{ID:42413494 Type:12 Tamper:{Phy:02 Enc:00} Consumption:  428602 CRC:0xFCD0}}
{Time:2019-01-03T19:17:41.152 SCM:{ID:41941394 Type:12 Tamper:{Phy:01 Enc:00} Consumption:  655820 CRC:0xC40D}}
{Time:2019-01-03T19:17:47.540 SCM:{ID:31333509 Type:13 Tamper:{Phy:00 Enc:02} Consumption:   41359 CRC:0x00F9}}
{Time:2019-01-03T19:17:54.596 SCM:{ID:31333509 Type:13 Tamper:{Phy:00 Enc:02} Consumption:   41359 CRC:0x00F9}}

The next step is to find out which meter is yours and then log the value somewhere.