Dying SSD: Difference between revisions

From Leo's Notes
This page was last edited on 15 June 2020, at 00:41.
another ssd failing
m Text replacement - "Category:Hardware" to "{{Navbox Hardware}}Category:Hardware"
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
== Crutial M4 ==
== Crucial M4 ==
I believe this SSD is dying since Windows will randomly blue screen after some time. Interestingly, the computer fails to boot afterwards until a full power cycle of the computer (ie. flipping the power switch off and on).
I believe this SSD is dying since Windows will randomly blue screen after some time. Interestingly, the computer fails to boot afterwards until a full power cycle of the computer (ie. flipping the power supply switch off and on).


After one of these BSOD events, I booted into Linux and found the drive in a read-only state even when mounted as rw. When iterating over all the files, I get the following errors:
After one of these BSOD events, I booted into Linux and found the drive in a read-only state even when mounted as rw. When iterating over all the files, I get the following errors:
{{highlight|lang=terminal|code=
{{highlight|lang=terminal|code=
# dmesg  # After running 'find | tail' to iterate over all file listings
# dmesg  # After running 'find {{!}} tail' to iterate over all file listings
[    2.779403] ata10: SATA max UDMA/133 abar m512@0xf7110000 port 0xf7110180 irq 59
[    2.779403] ata10: SATA max UDMA/133 abar m512@0xf7110000 port 0xf7110180 irq 59
[    3.269481] ata10: SATA link up 6.0 Gbps (SStatus 133 SControl 300)
[    3.269481] ata10: SATA link up 6.0 Gbps (SStatus 133 SControl 300)
Line 165: Line 165:
== Kingston 64GB ==
== Kingston 64GB ==


When my Kingston 64GB started failing, I took a dump of the SMART output just for future reference. Unlike a traditional disk, the <code>'''Reallocated_Sector_Ct'''</code> value does not go up, possibly because this SSD does not support sector relocation. It's also interesting to note that the SMART values make it ''appear'' to be fine, this disk was on its death bed.
When my Kingston 64GB started failing, I took a dump of the SMART output just for future reference. Unlike a traditional disk, the {{code|'''Reallocated_Sector_Ct'''}} value does not go up, possibly because this SSD does not support sector relocation. It's also interesting to note that the SMART values make it ''appear'' to be fine, this disk was on its death bed.


If your SMART output looks like the one below, it is probably toast. This one died a few days after where I couldn't successfully create an image from it.
If your SMART output looks like the one below, it is probably toast. This one died a few days after where I couldn't successfully create an image from it.


smartctl 5.43 2012-05-01 r3539 [x86_64-linux-3.2.0-2-amd64] (local build)
{{highlight|lang=text|code=
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
smartctl 5.43 2012-05-01 r3539 [x86_64-linux-3.2.0-2-amd64] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
 
Model Family:    JMicron based SSDs
=== START OF INFORMATION SECTION ===
Device Model:    KINGSTON SNV425S264GB
Model Family:    JMicron based SSDs
Serial Number:    07MA20047524
Device Model:    KINGSTON SNV425S264GB
Firmware Version: C091126a
Serial Number:    07MA20047524
User Capacity:    64,023,257,088 bytes [64.0 GB]
Firmware Version: C091126a
Sector Size:      512 bytes logical/physical
User Capacity:    64,023,257,088 bytes [64.0 GB]
Device is:        In smartctl database [for details use: -P show]
Sector Size:      512 bytes logical/physical
ATA Version is:  8
Device is:        In smartctl database [for details use: -P show]
ATA Standard is:  Exact ATA specification draft version not indicated
ATA Version is:  8
Local Time is:    Wed Oct  3 19:19:41 2012 UTC
ATA Standard is:  Exact ATA specification draft version not indicated
SMART support is: Available - device has SMART capability.
Local Time is:    Wed Oct  3 19:19:41 2012 UTC
SMART support is: Enabled
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
 
SMART overall-health self-assessment test result: PASSED
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
 
Offline data collection status:  (0x00) Offline data collection activity
General SMART Values:
was never started.
Offline data collection status:  (0x00) Offline data collection activity
Auto Offline Data Collection: Disabled.
was never started.
Self-test execution status:      (  0) The previous self-test routine completed
Auto Offline Data Collection: Disabled.
without error or no self-test has ever  
Self-test execution status:      (  0) The previous self-test routine completed
been run.
without error or no self-test has ever  
Total time to complete Offline  
been run.
data collection: (  30) seconds.
Total time to complete Offline  
Offline data collection
data collection: (  30) seconds.
capabilities: (0x1b) SMART execute Offline immediate.
Offline data collection
Auto Offline data collection on/off support.
capabilities: (0x1b) SMART execute Offline immediate.
Suspend Offline collection upon new
Auto Offline data collection on/off support.
command.
Suspend Offline collection upon new
Offline surface scan supported.
command.
Self-test supported.
Offline surface scan supported.
No Conveyance Self-test supported.
Self-test supported.
No Selective Self-test supported.
No Conveyance Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
No Selective Self-test supported.
power-saving mode.
SMART capabilities:            (0x0003) Saves SMART data before entering
Supports SMART auto save timer.
power-saving mode.
Error logging capability:        (0x01) Error logging supported.
Supports SMART auto save timer.
General Purpose Logging supported.
Error logging capability:        (0x01) Error logging supported.
Short self-test routine  
General Purpose Logging supported.
recommended polling time: (  1) minutes.
Short self-test routine  
Extended self-test routine
recommended polling time: (  1) minutes.
recommended polling time: (  1) minutes.
Extended self-test routine
recommended polling time: (  1) minutes.
SMART Attributes Data Structure revision number: 16
 
Vendor Specific SMART Attributes with Thresholds:
SMART Attributes Data Structure revision number: 16
ID# ATTRIBUTE_NAME          FLAG    VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
Vendor Specific SMART Attributes with Thresholds:
  1 Raw_Read_Error_Rate    0x000b  100  100  050    Pre-fail  Always      -      0
ID# ATTRIBUTE_NAME          FLAG    VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  2 Throughput_Performance  0x0005  100  100  050    Pre-fail  Offline      -      0
  1 Raw_Read_Error_Rate    0x000b  100  100  050    Pre-fail  Always      -      0
  3 Unknown_Attribute      0x0007  100  100  050    Pre-fail  Always      -      0
  2 Throughput_Performance  0x0005  100  100  050    Pre-fail  Offline      -      0
  5 Reallocated_Sector_Ct  0x0013  100  100  050    Pre-fail  Always      -      0
  3 Unknown_Attribute      0x0007  100  100  050    Pre-fail  Always      -      0
  7 Unknown_Attribute      0x000b  100  100  050    Pre-fail  Always      -      0
  5 Reallocated_Sector_Ct  0x0013  100  100  050    Pre-fail  Always      -      0
  8 Unknown_Attribute      0x0005  100  100  050    Pre-fail  Offline      -      0
  7 Unknown_Attribute      0x000b  100  100  050    Pre-fail  Always      -      0
  9 Power_On_Hours          0x0012  100  100  000    Old_age  Always      -      11087
  8 Unknown_Attribute      0x0005  100  100  050    Pre-fail  Offline      -      0
  10 Unknown_Attribute      0x0013  100  100  050    Pre-fail  Always      -      0
  9 Power_On_Hours          0x0012  100  100  000    Old_age  Always      -      11087
  12 Power_Cycle_Count      0x0012  100  100  000    Old_age  Always      -      626
10 Unknown_Attribute      0x0013  100  100  050    Pre-fail  Always      -      0
168 SATA_Phy_Error_Count    0x0012  100  100  000    Old_age  Always      -      294
12 Power_Cycle_Count      0x0012  100  100  000    Old_age  Always      -      626
175 Bad_Cluster_Table_Count 0x0003  100  100  010    Pre-fail  Always      -      2
168 SATA_Phy_Error_Count    0x0012  100  100  000    Old_age  Always      -      294
192 Unexpect_Power_Loss_Ct  0x0012  100  100  000    Old_age  Always      -      0
175 Bad_Cluster_Table_Count 0x0003  100  100  010    Pre-fail  Always      -      2
194 Temperature_Celsius    0x0022  042  100  020    Old_age  Always      -      42 (Min/Max 34/42)
192 Unexpect_Power_Loss_Ct  0x0012  100  100  000    Old_age  Always      -      0
197 Current_Pending_Sector  0x0012  100  100  000    Old_age  Always      -      0
194 Temperature_Celsius    0x0022  042  100  020    Old_age  Always      -      42 (Min/Max 34/42)
240 Unknown_Attribute      0x0013  100  100  050    Pre-fail  Always      -      0
197 Current_Pending_Sector  0x0012  100  100  000    Old_age  Always      -      0
170 Bad_Block_Count        0x0003  100  100  010    Pre-fail  Always      -      3 185 30
240 Unknown_Attribute      0x0013  100  100  050    Pre-fail  Always      -      0
173 Erase_Count            0x0012  100  100  000    Old_age  Always      -      7352 16898 9172
170 Bad_Block_Count        0x0003  100  100  010    Pre-fail  Always      -      3 185 30
173 Erase_Count            0x0012  100  100  000    Old_age  Always      -      7352 16898 9172
SMART Error Log Version: 1
 
ATA Error Count: 1002 (device log contains only the most recent five errors)
SMART Error Log Version: 1
CR = Command Register [HEX]
ATA Error Count: 1002 (device log contains only the most recent five errors)
FR = Features Register [HEX]
CR = Command Register [HEX]
SC = Sector Count Register [HEX]
FR = Features Register [HEX]
SN = Sector Number Register [HEX]
SC = Sector Count Register [HEX]
CL = Cylinder Low Register [HEX]
SN = Sector Number Register [HEX]
CH = Cylinder High Register [HEX]
CL = Cylinder Low Register [HEX]
DH = Device/Head Register [HEX]
CH = Cylinder High Register [HEX]
DC = Device Command Register [HEX]
DH = Device/Head Register [HEX]
ER = Error register [HEX]
DC = Device Command Register [HEX]
ST = Status register [HEX]
ER = Error register [HEX]
Powered_Up_Time is measured from power on, and printed as
ST = Status register [HEX]
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
Powered_Up_Time is measured from power on, and printed as
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1002 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
 
  When the command that caused the error occurred, the device was active or idle.
Error 1002 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
 
  ER ST SC SN CL CH DH
  After command completion occurred, registers were:
  -- -- -- -- -- -- --
  ER ST SC SN CL CH DH
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280
  -- -- -- -- -- -- --
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280
  Commands leading to the command that caused the error were:
 
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  Commands leading to the command that caused the error were:
  -- -- -- -- -- -- -- --  ----------------  --------------------
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
Error 1001 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
 
  When the command that caused the error occurred, the device was active or idle.
Error 1001 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
 
  ER ST SC SN CL CH DH
  After command completion occurred, registers were:
  -- -- -- -- -- -- --
  ER ST SC SN CL CH DH
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280
  -- -- -- -- -- -- --
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280
  Commands leading to the command that caused the error were:
 
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  Commands leading to the command that caused the error were:
  -- -- -- -- -- -- -- --  ----------------  --------------------
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
Error 1000 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
 
  When the command that caused the error occurred, the device was active or idle.
Error 1000 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
 
  ER ST SC SN CL CH DH
  After command completion occurred, registers were:
  -- -- -- -- -- -- --
  ER ST SC SN CL CH DH
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280
  -- -- -- -- -- -- --
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280
  Commands leading to the command that caused the error were:
 
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  Commands leading to the command that caused the error were:
  -- -- -- -- -- -- -- --  ----------------  --------------------
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
Error 999 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
 
  When the command that caused the error occurred, the device was active or idle.
Error 999 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
 
  ER ST SC SN CL CH DH
  After command completion occurred, registers were:
  -- -- -- -- -- -- --
  ER ST SC SN CL CH DH
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280
  -- -- -- -- -- -- --
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280
  Commands leading to the command that caused the error were:
 
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  Commands leading to the command that caused the error were:
  -- -- -- -- -- -- -- --  ----------------  --------------------
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
Error 998 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
 
  When the command that caused the error occurred, the device was active or idle.
Error 998 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.
  After command completion occurred, registers were:
 
  ER ST SC SN CL CH DH
  After command completion occurred, registers were:
  -- -- -- -- -- -- --
  ER ST SC SN CL CH DH
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280
  -- -- -- -- -- -- --
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280
  Commands leading to the command that caused the error were:
 
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  Commands leading to the command that caused the error were:
  -- -- -- -- -- -- -- --  ----------------  --------------------
  CR FR SC SN CL CH DH DC  Powered_Up_Time  Command/Feature_Name
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  -- -- -- -- -- -- -- --  ----------------  --------------------
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
SMART Self-test log structure revision number 1
 
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
SMART Self-test log structure revision number 1
# 1  Extended offline    Completed without error      00%    11087        -
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 2  Extended offline    Completed without error      00%      9255        -
# 1  Extended offline    Completed without error      00%    11087        -
# 2  Extended offline    Completed without error      00%      9255        -
Device does not support Selective Self Tests/Logging
 
Device does not support Selective Self Tests/Logging
}}
 
 
{{Navbox Hardware}}[[Category:Hardware]]

Latest revision as of 00:41, 15 June 2020

Crucial M4

I believe this SSD is dying since Windows will randomly blue screen after some time. Interestingly, the computer fails to boot afterwards until a full power cycle of the computer (ie. flipping the power supply switch off and on).

After one of these BSOD events, I booted into Linux and found the drive in a read-only state even when mounted as rw. When iterating over all the files, I get the following errors:

# dmesg  # After running 'find | tail' to iterate over all file listings
[    2.779403] ata10: SATA max UDMA/133 abar m512@0xf7110000 port 0xf7110180 irq 59
[    3.269481] ata10: SATA link up 6.0 Gbps (SStatus 133 SControl 300)
[    3.269924] ata10.00: ATA-9: M4-CT064M4SSD2, 070H, max UDMA/100
[    3.269928] ata10.00: 125045424 sectors, multi 16: LBA48 NCQ (depth 31/32), AA
[    3.270436] ata10.00: configured for UDMA/100
[  160.455028] ata10.00: exception Emask 0x10 SAct 0x3 SErr 0x1390002 action 0xe frozen
[  160.455243] ata10.00: irq_stat 0x88400000, interface fatal error, PHY RDY changed
[  160.455766] ata10: SError: { RecovComm PHYRdyChg 10B8B Dispar BadCRC TrStaTrns }
[  160.456232] ata10.00: failed command: READ FPDMA QUEUED
[  160.456785] ata10.00: cmd 60/00:00:08:41:07/01:00:00:00:00/40 tag 0 ncq 131072 in
[  160.457783] ata10.00: status: { DRDY }
[  160.458343] ata10.00: failed command: READ FPDMA QUEUED
[  160.458818] ata10.00: cmd 60/08:08:f0:d2:64/00:00:00:00:00/40 tag 1 ncq 4096 in
[  160.459883] ata10.00: status: { DRDY }
[  160.460454] ata10: hard resetting link
[  161.183274] ata10: SATA link down (SStatus 0 SControl 300)
[  164.468273] ata10: hard resetting link
[  164.956796] ata10: SATA link up 6.0 Gbps (SStatus 133 SControl 300)
[  164.957630] ata10.00: configured for UDMA/100
[  164.957643] ata10: EH complete
[  274.151510] ata10.00: exception Emask 0x10 SAct 0x3 SErr 0x1390002 action 0xe frozen
[  274.151672] ata10.00: irq_stat 0x88400000, interface fatal error, PHY RDY changed
[  274.152065] ata10: SError: { RecovComm PHYRdyChg 10B8B Dispar BadCRC TrStaTrns }
[  274.152481] ata10.00: failed command: READ FPDMA QUEUED
[  274.152895] ata10.00: cmd 60/08:00:a8:b1:b6/00:00:02:00:00/40 tag 0 ncq 4096 in
[  274.153730] ata10.00: status: { DRDY }
[  274.154153] ata10.00: failed command: READ FPDMA QUEUED
[  274.154574] ata10.00: cmd 60/00:08:50:5d:65/01:00:00:00:00/40 tag 1 ncq 131072 in
[  274.155465] ata10.00: status: { DRDY }
[  274.155917] ata10: hard resetting link
[  274.877700] ata10: SATA link down (SStatus 0 SControl 300)
[  278.164775] ata10: hard resetting link
[  278.655222] ata10: SATA link up 6.0 Gbps (SStatus 133 SControl 300)
[  278.656040] ata10.00: configured for UDMA/100
[  278.656054] ata10: EH complete

The SMART output is:

smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.13.0-24-generic] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Crucial/Micron RealSSD m4/C400/P400
Device Model:     M4-CT064M4SSD2
Serial Number:    00000000121009082266
LU WWN Device Id: 5 00a075 109082266
Firmware Version: 070H
User Capacity:    64,023,257,088 bytes [64.0 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Sun Feb 19 00:45:04 2017 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x80) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (  295) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (   4) minutes.
Conveyance self-test routine
recommended polling time:        (   3) minutes.
SCT capabilities:              (0x003d) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   100   100   050    Pre-fail  Always       -       0
  5 Reallocated_Sector_Ct   0x0033   099   099   010    Pre-fail  Always       -       0 (0 2)
  9 Power_On_Hours          0x0032   100   100   001    Old_age   Always       -       8579
 12 Power_Cycle_Count       0x0032   100   100   001    Old_age   Always       -       1034
170 Grown_Failing_Block_Ct  0x0033   099   099   010    Pre-fail  Always       -       64
171 Program_Fail_Count      0x0032   100   100   001    Old_age   Always       -       124
172 Erase_Fail_Count        0x0032   100   100   001    Old_age   Always       -       0
173 Wear_Leveling_Count     0x0033   098   098   010    Pre-fail  Always       -       72
174 Unexpect_Power_Loss_Ct  0x0032   100   100   001    Old_age   Always       -       12
181 Non4k_Aligned_Access    0x0022   100   100   001    Old_age   Always       -       1207 375 832
183 SATA_Iface_Downshift    0x0032   100   100   001    Old_age   Always       -       0
184 End-to-End_Error        0x0033   100   100   050    Pre-fail  Always       -       0
187 Reported_Uncorrect      0x0032   100   100   001    Old_age   Always       -       0
188 Command_Timeout         0x0032   100   100   001    Old_age   Always       -       0
189 Factory_Bad_Block_Ct    0x000e   100   100   001    Old_age   Always       -       49
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       -       0
195 Hardware_ECC_Recovered  0x003a   100   100   001    Old_age   Always       -       0
196 Reallocated_Event_Count 0x0032   100   100   001    Old_age   Always       -       64
197 Current_Pending_Sector  0x0032   100   100   001    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0030   100   100   001    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   100   100   001    Old_age   Always       -       0
202 Perc_Rated_Life_Used    0x0018   098   098   001    Old_age   Offline      -       2
206 Write_Error_Rate        0x000e   100   100   001    Old_age   Always       -       124

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

The SSD is read-only:

root@ClonezillaAlt:/mnt/disk/Users/Leo/Desktop# mount
/dev/sde2 on /mnt/disk type fuseblk (rw,nosuid,nodev,allow_other,blksize=4096)

root@ClonezillaAlt:/mnt/disk/Users/Leo/Desktop# ls
desktop.ini

root@ClonezillaAlt:/mnt/disk/Users/Leo/Desktop# rm desktop.ini

root@ClonezillaAlt:/mnt/disk/Users/Leo/Desktop# echo "test" > test.txt
bash: test.txt: No such file or directory

root@ClonezillaAlt:/mnt/disk/Users/Leo/Desktop# ls
desktop.ini

Kingston 64GB

When my Kingston 64GB started failing, I took a dump of the SMART output just for future reference. Unlike a traditional disk, the Reallocated_Sector_Ct value does not go up, possibly because this SSD does not support sector relocation. It's also interesting to note that the SMART values make it appear to be fine, this disk was on its death bed.

If your SMART output looks like the one below, it is probably toast. This one died a few days after where I couldn't successfully create an image from it.

smartctl 5.43 2012-05-01 r3539 [x86_64-linux-3.2.0-2-amd64] (local build)
Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     JMicron based SSDs
Device Model:     KINGSTON SNV425S264GB
Serial Number:    07MA20047524
Firmware Version: C091126a
User Capacity:    64,023,257,088 bytes [64.0 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  Exact ATA specification draft version not indicated
Local Time is:    Wed Oct  3 19:19:41 2012 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(   30) seconds.
Offline data collection
capabilities: 			 (0x1b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					No Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 (   1) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       -       0
  2 Throughput_Performance  0x0005   100   100   050    Pre-fail  Offline      -       0
  3 Unknown_Attribute       0x0007   100   100   050    Pre-fail  Always       -       0
  5 Reallocated_Sector_Ct   0x0013   100   100   050    Pre-fail  Always       -       0
  7 Unknown_Attribute       0x000b   100   100   050    Pre-fail  Always       -       0
  8 Unknown_Attribute       0x0005   100   100   050    Pre-fail  Offline      -       0
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       -       11087
 10 Unknown_Attribute       0x0013   100   100   050    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0012   100   100   000    Old_age   Always       -       626
168 SATA_Phy_Error_Count    0x0012   100   100   000    Old_age   Always       -       294
175 Bad_Cluster_Table_Count 0x0003   100   100   010    Pre-fail  Always       -       2
192 Unexpect_Power_Loss_Ct  0x0012   100   100   000    Old_age   Always       -       0
194 Temperature_Celsius     0x0022   042   100   020    Old_age   Always       -       42 (Min/Max 34/42)
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
240 Unknown_Attribute       0x0013   100   100   050    Pre-fail  Always       -       0
170 Bad_Block_Count         0x0003   100   100   010    Pre-fail  Always       -       3 185 30
173 Erase_Count             0x0012   100   100   000    Old_age   Always       -       7352 16898 9172

SMART Error Log Version: 1
ATA Error Count: 1002 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1002 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA

Error 1001 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA

Error 1000 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA

Error 999 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA

Error 998 occurred at disk power-on lifetime: 11087 hours (461 days + 23 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 18 01 00 e0  Error: UNC at LBA = 0x00000118 = 280

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  ef 03 45 00 00 00 a0 08      00:03:09.900  SET FEATURES [Set transfer mode]
  ec 00 00 00 00 00 a0 08      00:03:09.900  IDENTIFY DEVICE
  c8 00 08 18 01 00 e0 08      00:03:09.900  READ DMA

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     11087         -
# 2  Extended offline    Completed without error       00%      9255         -

Device does not support Selective Self Tests/Logging