Crucial V4 SSD

From Leo's Notes
Last edited on 15 June 2020, at 00:43.

This is a 'dead' SSD after a firmware update which wiped all the smart data:

# smartctl -a /dev/sdc
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.8.6-300.fc25.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     V4-CT032V4SSD2
Serial Number:    200097926
LU WWN Device Id: 5 00a075 60bed4086
Firmware Version: S5FAMM25
User Capacity:    32,017,047,552 bytes [32.0 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Mon May 29 22:18:28 2017 MDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (  255) seconds.
Offline data collection
capabilities:                    (0x1b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (   2) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0012   100   100   000    Old_age   Always       -       2
 33 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       -       160
168 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       -       0
177 Wear_Leveling_Count     0x0003   100   100   010    Pre-fail  Always       -       1
181 Program_Fail_Cnt_Total  0x0003   100   100   000    Pre-fail  Always       -       0
182 Erase_Fail_Count_Total  0x0003   100   100   000    Pre-fail  Always       -       0
192 Power-Off_Retract_Count 0x0012   100   100   000    Old_age   Always       -       0
170 Unknown_Attribute       0x0003   100   100   010    Pre-fail  Always       -       10
173 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       -       50
218 Unknown_Attribute       0x000b   100   100   050    Pre-fail  Always       -       0
231 Temperature_Celsius     0x000b   100   100   000    Pre-fail  Always       -       100
232 Available_Reservd_Space 0x000b   100   100   000    Pre-fail  Always       -       0
233 Media_Wearout_Indicator 0x000b   100   100   000    Pre-fail  Always       -       0
241 Total_LBAs_Written      0x0013   100   100   000    Pre-fail  Always       -       0
242 Total_LBAs_Read         0x0013   100   100   000    Pre-fail  Always       -       0
246 Unknown_Attribute       0x0002   100   100   050    Old_age   Always       -       80

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported


# smartctl -a /dev/sdc
smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.10.17-200.fc25.x86_64] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     V4-CT032V4SSD2
Serial Number:    200097926
LU WWN Device Id: 5 00a075 60bed4086
Firmware Version: S5FAMM25
User Capacity:    32,017,047,552 bytes [32.0 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      2.5 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 2.6, 3.0 Gb/s
Local Time is:    Tue May 30 01:05:36 2017 MDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                (  255) seconds.
Offline data collection
capabilities:                    (0x1b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        No Conveyance Self-test supported.
                                        No Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        (   2) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       -       2
 12 Power_Cycle_Count       0x0012   100   100   000    Old_age   Always       -       4
 33 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       -       160
168 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       -       0
177 Wear_Leveling_Count     0x0003   100   100   010    Pre-fail  Always       -       1
181 Program_Fail_Cnt_Total  0x0003   100   100   000    Pre-fail  Always       -       0
182 Erase_Fail_Count_Total  0x0003   100   100   000    Pre-fail  Always       -       0
192 Power-Off_Retract_Count 0x0012   100   100   000    Old_age   Always       -       1
170 Unknown_Attribute       0x0003   100   100   010    Pre-fail  Always       -       10
173 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       -       196664
218 Unknown_Attribute       0x000b   100   100   050    Pre-fail  Always       -       0
231 Temperature_Celsius     0x000b   100   100   000    Pre-fail  Always       -       99
232 Available_Reservd_Space 0x000b   100   100   000    Pre-fail  Always       -       0
233 Media_Wearout_Indicator 0x000b   100   100   000    Pre-fail  Always       -       11
241 Total_LBAs_Written      0x0013   100   100   000    Pre-fail  Always       -       2
242 Total_LBAs_Read         0x0013   100   100   000    Pre-fail  Always       -       0
246 Unknown_Attribute       0x0002   100   100   050    Old_age   Always       -       61095

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

Selective Self-tests/Logging not supported